[1] _' Relay Ohmmeter Tests

131 D_R2_1_4J9

INotel Throughout this section two symbols are used to interpret electrical troubleshooting resultsUse continuity light or ohmmeter calibrated on low ohms scale to test continuity
[!] This symbol indicates continuity or very low resistance This symbol indicates no continuity or very high resistance (00)INot To avoid damaging components or troubleshooting equipe men!, disconnect the battery cables and remove the relays before proceeding

_ _ DR2149

1Use continuity light or ohmmeter calibrated on low ohms scale to test continuityrJl 2Connect meter leads to relay terminals 87a and 30 The meter must show continuityf41 3Connect meter leads to relay terminals 87 and 30 The meter must show no continuity