Starter Circuit CheckRemote Control Models INotel Battery must be fully charged

Procedure Remove black lead from ground at G)' Connect voltmeter between CD and common engine groundTurn key to START positionVoltmeter should show battery voltageConnect meter at START position
Result aIf no reading, go to Step

Check voltage between ground and

Steps thru Remove starter to solenoid cable from (i) to prevent starter engagement while making checksbetween ground

bIf meter reads battery voltage, reconnect black lead to ground and go to Step

I!I Check voltage li1 and

aIf meter reads battery voltage, lead is open between CD and

INotel Steps thru Turn key OFF before connecting and disconnecting meterTurn key to START position after connecting