1991 Johnson Evinrude EI 60 Loop V Models 150, 175 outboards Service Manual, Page 223Get this manual

1991 Johnson Evinrude EI 60 Loop V Models 150, 175 outboards Service Manual, Page 223

High Voltage r;J In some conditions, the key switch may be shorting (allowing LJ some leakage) to the other terminals in the key switch, but will not show up with test light or an ohmmeterThis condition may be found by using condenser tester (leakage test) where voltage of approximately 500 volts is applied to the key switch terminalsWith all leads disconnected and the key switch in the OFF position, connect the black lead of the tester to one of the "M" terminals of the key switch1Attach the red lead apply leakage test824006
of the tester to the "B" terminal and

2Repeat test by moving the red lead to each of the terminals and applying the leakage testThe meter will indicate if leakage is present3When applying test to other "M" terminal, turn key to the ON position