1990 Johnson Evinrude "ES" Cross V 88 thru 115, 150 thru 175, P/N 507874, Page 290Get this manual

1990 Johnson Evinrude "ES" Cross V 88 thru 115, 150 thru 175, P/N 507874, Page 290

Running Test, Alternator Output
INote Disconnect
battery cables before proceeding with this

1Remove the rectifier red lead from the terminal board or the rectifier regulator red lead from the battery side of the starter solenoid

1500 2500 3500 4500 5500

2Wire to 40 amp ammeter in series with the rectifier red lead and the wiring harness red lead or in series with the rectifier regulator red lead and the battery side of the starter solenoid Guard against any red wire, its terminals, or the ammeter coming in contact with engine ground while the engine is runningContact may cause arcing""

3The engine's battery should not be fully charged when beginning this testConnect the battery cables and run the engine in test tankRefer to the output curves to determine the correct output-to-rpm ratio for your engine On unregulated systems: If there is no output or the output is not correct, refer to the stator and rectifier ohmmeter tests in this section On regulated systems: If there is no output or the output is not correct, refer to the stator ohmmeter and rectifierregulator runnings tests in this section