Starter Circuit CheckRemote
Step Procedure Remove black lead from ground Result aIf meter does not read any voltage, proceed to STEP 2bI meter reads 12 volts (battery voltage) reconnect black lead to ground and proceed to STEP 6
Check voltage between ground and point

Steps thruRemove starter to solenoid cable from check point to prevent starter engagement while making checks
CD Connect voltmeter between point CD
at check point and common groundTurn key switch to start positionVoltmeter should show .12 volts (battery voltage)
Check voltage between ground and point

Connect meter at

switch to "start" position
aIf meter reads 12 volts (battery voltage), lead is open between

In STEPS thru turn key to "off" position before disconnecting and connecting meterTurn key to "start" position after making con nection where requiredCheck voltage between ground and point Connect meter at