High Voltage In some conditions, the key switch may be shorting (some leakage) to the other terminals in the key switch, but will not show up with test light or an ohmmeterThis condition may be found by using condenser tester (leakage test) where voltage of approximately 500 volts is applied to the key switch terminalsWith all leads disconnected and the key switch in the "OFF" position, connect the black lead of the tester to one of the "M" terminals of the key switch 1Attach the red lead apply leakage test [IT!

of the tester to the "8" terminal and

2Repeat test by moving the red lead to each of the terminals and applying the leakage test The meter will indicate if leakage is present3When applying test to other "M" terminal, turn key to the "ON" position
Start Switch Ohmmeter CheckTE
Disconnect the two switch leads from the starter solenoid 1Set an ohmmeter to high ohms scaleAttach one ohmmeter lead to switch yellow red lead and the other ohmmeter lead to switch red leadDepress switch2Ohmmeter should show very low reading (zero) when switch is depressed and very high reading (00) when switch is released Electric start modelsTo replace start switch, remove two wires from start switch to starter solenoidRemove nut on start switch and remove assemblyWhen installing, refer to Wiring Diagram for correct wiring