1989 Johnson Evinrude "CE" 9.9 thru 30 Service Manual, P/N 507754, Page 132Get this manual

1989 Johnson Evinrude "CE" 9.9 thru 30 Service Manual, P/N 507754, Page 132

Engine Temperature Check The Markal Thermomelt Stik is heat sensitive marker that melts on contact with surface of specific temperature One source for Thermomelt Stiks is Stevens Instrument Company

At least two Thermomelt Stiks or digital pyrometer should be used to accurately determine the engine's operating temperatures6469

The Thermomelt Stik mark will appear dull and chalky when the surface marked is below the Stik's rated temperature When the surface exceeds the Stik's rated temperature, the mark will appear liquid and glossy

To achieve accurate and consistent readings, engine temper ature must be gauged at the top of cylinder head
fN=J For the

following engine operating temperatures and RPM figures to be correct, the inlet water temperature must be 700 100 (21 C)
Pyrometer Procedure 1Install correct test propeller and place engine in test tank