1988 Johnson Evinrude "CC" 9.9 thru 30 Service Manual, P/N 507660, Page 113Get this manual

1988 Johnson Evinrude "CC" 9.9 thru 30 Service Manual, P/N 507660, Page 113

Check for correct positioning of float levelFloat level controls the he ght of fuel in the float chamber and is very critical with regard to carburetor calibration and function Turn carburetor body upside down and hold so gasket surface is horizontallhe weight of the float will dose the float valve needleRest OMC Float Gauge PIN 324891 on gasket surface, and slide gauge U,Q next to floatTop of float should be between notches on float gaugeBe certain gauge is not holding down the float If float level is not between the notches of gauge, lightly bend metal float arm to adjust levelBe careful not to force float needle valve into seatCheck for correct float drop dimensionThis dimension affects the full opening of the inlet needle and is critical to correct operation of the carburetorWith carburetor body in normal running position, the float must drop open to dimension shownTo adjust, bend tab on float arm where tab contacts float seat III] Base of Carburetor Body