f316Test resistance of high tension leads on low ohms scaleResistance should be near zeroCoil Power TestAll Models

Do not exceed maximum specified amperage when testing '1 COl
Colt, Junior and 4BR ModelsConnect the black lead of the tester to the ground lead of the coilConnect the red lead of the tester to the coil's breaker point lead Connect the high tension lead of the tester to the coil's secondary terminalTurn on the meter and slowly increase the coil currentNote the meter reading when the spark jumps gap steadily steady spark at or before maximum specified amperage indicates good coil If steady spark does not occur at or before maximum amperage, replace the coil

813301 _ J

rl Magneto C.DModelsThe magneto C.Dignition coil is tested with reverse polarity connections Connect the black lead of the tester to the primary terminal of the coil and the tester's red lead to the ground tab Connect the high tension lead of the tester to the high tension lead of the coil