5Grease cable trunnion pocket and insert cable trunnion into trunnion pocket in housing half 6The throttle lever arm must be in the idle position before reassembl Move the throttle lever arm forward toward the front of the housing half until it contacts the stop7Grease trunnion pocket in cover halfGrease cable pin and place eyelet of shift cable between the shift lever halves, and press cable trunnion into trunnion pocket in cover halfInsert cable pin 8Shift lever arm must be in neutral before reassembly of remote controlPosition neutral start switch oncenter Lll of neutral start cam while making sure neutral lock slide of control handle is engaged in notchControl handle should not be able to move without releasing neutral lock slideI the neutral lock slide does not engage notch in index plate when neutral switch is centered on neutral cam, it will be necessary to reposition either the control handle or the index plateReassemble two halves of remote control by positioning housing half onto cover half while cover half is on flat surfaceFlat surface will keep cable pins from falling outTake care to properly pilot the electrical cable grommet into the housingTighten the three cover screws to torque of 4,6-5,5 Nm (40-50 inIbs9