17Apply OMC Triple-Guard Grease or Lubriplate 777 to the handle end of the starter ropeUsing OMC Special Tool PI 378774 (Starter Rope Threading Tool), thread the starter rope through the handlePress the starter rope into the channel of the rope anchor, with end of starter rope butting firmly against end of channelPress the anchor into the handle18Check operation of the starter pawl when the starter rope is pulled outThe starter pawl should extend when the starter rope is pulled and retract when the starter rope recoils 19Install the starter lockout assembly to the starter housing using the shou Ider screwTighten the shou Ider screw secu relyCOA1373
Installation of Starter65
1Position the starter assembly onto the motorPlace the lifting ring on the rear screw mounting bossInstall the five starter housing retaining screwsBe sure to place washers between the starter housing rubber mounts and the motorTighten the two starter housing screws and one nut to torque of 14-16 Nm (10-12 ftIbsTighten the two starter handle bracket screws to torque of 7-9 Nm (60-84 inIbs2If equipped with starter interlock, apply OMC Triple-Guard Grease or Lubriplate 777 to the starter lockout slide area of the starter housingPlace the starter lockout slide in the channel of the starter housingLoosely secure the starter lockout cable to the starter housing with cable clamp and screw Shift the motor to "Neutral" positionAdjust starter lockout cable so that starter lockout slide is centered on the lockout lever Tighten the cable clamp screw securely