SAFETY WARNING voltage which could present shock hazard is applied to the condenser in the leakage testHandle leads carefully and turn selector switch to "Discharg'e" before disconnecting leads from condenser after performing this testPOINT
It is possible to check the electrical condition of the points with the ig-

nition analyzerConnect test lead to the breaker and connect the second test lead to the breaker assembly screw terminalIf the points good, meter reading will in the green the "Breaker Test" scaleIf reading is in red area, do not immediately reject the points, but check the test lead connections to make sure that they tightsecure contact is necessary because of the current used in this testSee Figure 4-13
Figure 4-13Breaker Point Testing

NEVER FILE POINTS to bring reading within the green ("good") Reject the points if cleaning with alcohol does not give satisfactory reading