1979 Evinrude 4 HP Outboards Service Manual, PN 5424, Page 43Get this manual

1979 Evinrude 4 HP Outboards Service Manual, PN 5424, Page 43

eResistance of the primary winding should be 0.1 0.05 ohmsfCalibrate the ohmmeter to high ohm scale, then connect the meter red lead (+) to the "S" terminal jumper wireConnect the meter black lead (-) to the terminal inside the high tension lead coverSee Figure 4-28 general information is given hereSee Coil Specifications, Section 2IGNITION COIL TESTING (IGNITION COIL MUST SE REMOVED FROM POWER HEAD FOR POWER AND LEAKAGE TESTING

SAFETY WARNING
To avoid possible shock hazards and to prevent leakage, perform all tests to the coil on wooden or insulated bench top
If the ignition coil is good, the tester's meter will fall within the good area, with the primary circuit adjusted as specifiedConnect the test leads from the ignition tester to the coilConnect the black lead of the tester to the orange lead of the ignition coil and the tester's red lead to the coils orangeblack stripe ground lead Connect the high tension lead of the tester to the high tension lead (secondary) of the ignition coilWith the tester set to coil index (or operating amperageMerc-O-Tronic illustrated, adjusted as specifiednote meter reading See Figure 4-29A low reading on the tester indicates weak coil which must be replacedA dead coil will show no reading