DESCRIPTION The hydraulic assist shift remote control unit is comprised of combination throttle and gearshift selection lever, warm-up speed control, starting and ignition switch, choke switch, start-in-neutral only switch, and motor temperature warning hornSee Figure 8-1
OPERATION
The start-in-neutral only switch in the control unit completes the starting circuit only when the control lever is in NEUTRAL pOSitionThe circuit is open when the control lever is in either FORWARD or REVERSE positions and the key switch is inactiveWith the control lever in NEUTRAL position, the warm-up lever must be moved to START positionAfter starting and warm-up, the warm-up lever should be moved to RUN positionSee Figure 8-2
123456789101112
Throttle control clevis Bushing Starting ignition switch Choke switch Electric cable grommet Motor temperature warning horn Detent ball and spring cover Shift control clevis Control lever friction adjustment Start in neutral only switch Throttle cam Warm-up lever stop adjustment screw