1976 Evinrude 200 HP Outboards Service Manual, PN 5199, Page 155Get this manual

1976 Evinrude 200 HP Outboards Service Manual, PN 5199, Page 155

ALTERNATOR OUTPUT CHECK STEPaDisconnect the yellow lead from the voltage regulator to terminal block terminal #1

1Starter solenoid 2To accessories

bDisconnect the two red with purple stripe leads from terminal block #5Connect to 15 amp ammeter between the two redpurple leadsConnect the redpurple lead from the rectifier to the "G" side of the ammeter and the other redpurple lead to the "B" side of the ammetercRun the engine up to approximately 4500 rpmThe ammeter should show full charge (approximately 15 amps)dReconnect the redpurple leads to terminal block number 5Reconnect yellow lead from regulator to terminal block number 1
3Ammeter 4Battery

AMMETER FROM RECTIFIER RED PURPLE FROM MOTOR CABLE REDPURPLE

RECTIFIER CHECK STEPaCAUTION: Shut off engine and disconnect battery before checking, rectifierUse ohmmeterHigh ohm scalebDisconnect rectifier leadscConnect one ohmmeter probe to common engine ground, other probe to one yellow leaddNote readingreverse probesnote readingeReading on one check, no reading (infinity) on other checkdiode okfRepeat test using yellowgray rectifier lead and same values