1972 Evinrude StarFlire 125 HP Outboards Service Manual, PN 4822, Page 99Get this manual

1972 Evinrude StarFlire 125 HP Outboards Service Manual, PN 4822, Page 99

DESCRIPTION
The Selectric shift remote control consists of the throttle control lever, ignition switch, choke switch, motor temperature warning horn, push botton selector switch and blocking diode
NOTE: ALL WIRE CONNECTIONS SHOULD BE RE-SEALED WITH NEOPRENE PART NO 315417 ON REASSEMBLY

DISASSEMBL Y
The remote control is simple mechanism and will be found to be relatively trouble-freeSee Figure 8-1It may occasionally be necessary, however, to disassemble the remote control to check the operation of the push button switchProceed as follows: aDisconnect batteryRemove side platebDisconnect throttle cable from control box by removing casing guide from throttle leverRemove control cable from housingcDetach remote control from boatdRemove choke switch
PUSH BUTTON SWITCH

CABLE GROMMET

CABLE CLAMP

eRemove key switch1I NOTE: Carefully identify all wires and terminals when removing any remote control electrical partfRemove push-button cover plate and screws attaching selector switch to housingRemove switch and disconnect leadsSee Figure 8-4gDisconnect "HOT" horn leads and remove two mounting screwshRemove throttle lever pivot screwLift throttle lever from housingSee Figure l.l-2 KNOB