High voltage is applied to the condenser in the leakage testHandle leads carefully and turn selector switch to "Discharge" before disconnecting leads from condenser after performing this testBREAKER POINT TESTING
It is possible to check the electrical condition of the points with the ig-

nition analyzerConnect 'one test lead to the breaker arm, and connect the second test lead to the breaker assembly screw terminal

Figure 4-13Breaker Point Testing

If the points are good, meter reading will be in the green area on the "Breaker Test" scaleIf reading is in red area, do not immediately