CONDENSER TESTING The analyzer provides three tests of denser condition: condenser leakage, condenser sistance, and condenser capacityRefer to Section of this manual for condenser specificationsThe condenser tested while mounted the armature plate disconnecting the lead from the breaker assemblyConnect test lead to the breaker plate the condenser mounting clip if test is made off the plate) and connect second test lead to condenser pigtail leadThe condenser should replaced if it fails to meet of the thre testsSee Figure 4-11 NOTE NEVER FILE POINTS to bring reading within the green ("good") Reject the points if cleaning with trichlorethylene does not give satisfactory reading
Spark plug high tension leads tested for leakage insulation failures using the ignition analyzer and Connect the coil to the ignition analyzer as for the coil testConnect separa te test lead with suitable clips to the secondary terminal of the coil and the conductor of the spa rk plug lead being testedthe entire surface of the lead insulation with the grounded test See Figure 4-13Flashover will apparent wherever the insulation has broken down, due to moisture