mounted the armature plate disconnecting the lead from the breaker assemblyConnect test lead to the breaker plate the condenser mounting clip if test is made the plate) and connect second test lead to condenser pigtail leadThe condenser should replaced if it fails to meet of the three testsSee Figure 4-11 but check the test lead connections to make sure that they tightsecure contact is necessary because of the current used in this testSee Figure 4-12
NOTE NEVER FILE POINTS to bring reading within the green ("good") Reject the points if cleaning with trichlorethylene does not give satisfactory reading
voltage is applied to the condenser in the leakage test Handle leads carefully and turn selector switch to "Discharge" before disconnecting leads from condenser
TESTING Spark plug high tension leads tested for leakage insulation faHures using the ignition alyzer and Connect the to the ignition analyzer as for the coil testConnect separate