14-60 ELECTRICAL SYSTEM Multifunction Meter
Using the auxiliary wires, connect the 12 battery to the meter unit connector as follows OConnect the battery positive terminal to the terminal [1] OConnect the battery negative terminal to the terminal [2] +1 "- V
JNI7073BS C

Connect the terminal [3] to the terminal [1]
JHI10 74R SI C

When the terminal are connectedconfirm whether the display function operates as follows OThe fuel level gauge [A] and boost meter [B] momentary points to the last readingand then return to the position OThe other LCD segments [C] appear for several secondsOThe LED warning light [0] is litIf the display function does not operatereplace the meter unit Check that when the terminal [3] is disconnectedall the LCD segments and LED warning light disappearIf the LCD segments and LED warning light do not disappear, replace the meter unit