ELECTRICAL SYSTEM 14-51 Kawasaki Smart Steering System
Steering Position Sensor Input Voltage Inspection
Measure the input voltage to the steering position sensor
OBe sure the battery is fully chargedOConnect digital voltmeter [A] to the lead connector [B] of the steering position sensor using the needle adapter set [C] Special Tool- Needle Adapter Set: 57001-1457 Connections to Steering Position Sensor Connector Meter (+) RIW Terminal Meter (-)

BK Terminal+
JNI S00 38 S2

OTurn the ignition switch ONOCenter the handlebar in the straight-ahead position OMeasure the input voltageSteering Position Sensor Input Voltage Standard: Battery Voltage