2007-2010 Kawasaki Ultra 250X/260X/260LX PWC Factory Service Manual, Page 389Get this manual

2007-2010 Kawasaki Ultra 250X/260X/260LX PWC Factory Service Manual, Page 389

14-30 ELECTRICAL SYSTEM Electric Starter System
Measure the diameter [A] of the commutator [B]Replace the starter motor with new one if the commutator diameter is less than the service limitCommutator Diameter Standard: 28 mm (1.1024 in Service Limit: 27 mm (1.063 in

GPll0B07S1

Using the hand tester rangemeasure the resistance between any two commutator segments [A] Special Tool- Hand Tester: 57001-1394

Armature Inspection

If there is high resistance or no reading (00between any two segments, winding is open and the starter motor must be replaced Using the highest hand tester rangemeasure the resistance between the segments and the shaft [B]If there is any reading at allthe armature has short and the starter motor must be replaced
O Even if the foregoing checks show the armature to be good, it may be defective in some manner not readily detectable within the hand testerIf all other starter motor and starter motor circuit components check good, but the starter motor still does not turn over or only turns over weakly, replace the starter motor with new one