2007-2010 Kawasaki Ultra 250X/260X/260LX PWC Factory Service Manual, Page 159Get this manual

2007-2010 Kawasaki Ultra 250X/260X/260LX PWC Factory Service Manual, Page 159

3-100 FUEL SYSTEM (OFI) Fuel Pump
Remove the front storage pocket (see HullEngine Hood chapter) Connect the hand tester (25 DC) [A] to the fuel pump lead connector [B]using the needle adapter set [C] Special ToolsHand Tester: 57001-1394 Needle Adapter Set: 57001-1457

Turn the ignition switch ON and push the lanyard key under the stop button Pushing the start buttonrun the engineseconds at idling to measure the power source voltage Wait 15 seconds before using the starter again Pump Power Source Voltage Connections Tester (+) Tester (-)

JCOR005BS I

WR lead [0]
Battery (-) Terminal [E]

If the reading is goodthe power source voltage is normalInspect the operating voltage If there is no battery voltagecheck the following:
Operating Voltage Inspection

Power Source Voltage at Pump Lead Connector Standard: Battery Voltage

Main Fuse 20 Wiring for Fuel Pump Power Source (see Fuel Pump Circuit in this chapter)

a Be sure the battery is fully charged Remove the front storage pocket (see HullEngine Hood chapter) Connect the hand tester [A] to the connector [B], using the needle adapter set [C]Special ToolsHand Tester: 57001-1394 Needle Adapter Set: 57001-1457