FUEL SYSTEM (OFI) 3-41 Charging Temperature Sensor (Service CodeCharacter-19PrET)
Charging Temperature Sensor RemovalInstallation CAUTION
Never drop the sensor, especially on hard surfaceSuch shock to the sensor can damage it
Remove: Seat (see Seat Removal in the HullEngine Hood chapter) Charging Temperature Sensor [A] Tighten:
TorqueCharging Temperature Sensor: 15 Nm (1.5 kgfm, 11 ft.lb)

Output Voltage Inspection NOTE
a Be sure the battery is fully charged Remove the ECU (see ECU Removal) Do not disconnect the connector Connect digital voltmeter [A] to the ECU connector [8], with the needle adapter setSpecial ToolNeedle Adapter Set: 57001-1457 Water Temperature Sensor Output Voltage Connections to ECU Meter (+)

lead (terminal 8)

BKIW lead (terminal 32)
JC 1613 BS C

Turn the ignition switch ON and push the lanyard key un der the stop button Pushing the start buttonrun the engineseconds at idling to measure the sensor output voltagea Wait 15 seconds before using the starter againOutput Voltage at ECU Standard: aboutat 20C (68F)