2-30 PERIODIC MAINTENANCE Periodic Maintenance Procedures Electrical System
Battery Charging Condition Inspection
Battery charging condition can be checked by measuring battery terminal voltage Disconnect the battery terminal cables (see Battery Removal in the Electrical System chapter)
CAUTION
Be sure to disconnect the negative terminal cable firstGPOa 0703S1

Measure the battery terminal voltage

If the reading is below the specifiedrefreshing charge is
required (see Refreshing Charge in the Electrical System chapter) Battery Terminal Voltage Standard: 12.8 or more

O Measure with digital voltmeter [AJ which can be read one decimal place voltage

12.0 , 11 .5 0

Refreshing charge Battery Charge () is required :"';: )I( II Note Good GPO B0704 S1