1992-1995 Kawasaki 750SX Service Manual, Page 152Get this manual

1992-1995 Kawasaki 750SX Service Manual, Page 152

ELECTRICAL SYSTEM 13-21 CDIgniter Remova
.Remove the electric case and open it Remove the igniter [A] and disconnect the connectors
CDIgniter Installation Note
.Apply non-permanent locking agent to the mounting bolts and torql,.le them
TorqueCDlllnller Mounting Boll8: 7.8 N-m (0.8 kg, 691n-1b)

CDllgniter Inspection
.Remove the COl igniter Set the hand tester to the ItO range, .zero it, and mark the measurements shown in the table If the tester readings are not as specified, replace the COl! igniter
Special ToolHand Tr (YOII): 57001-883

CAUTION
Use only Hand Tester (spectal tool: 57001-883) for Ills lastA

multl-meler oIher 11_"Kaw888kl Hand Tr may show d"rent readingsIf megger or mwill large-capacllr Is used,lbe COt .Ignller will be damaged