1992-1995 Kawasaki 750SX Service Manual, Page 143Get this manual

1992-1995 Kawasaki 750SX Service Manual, Page 143

13-12 ELECTRICAL SYSTEM
Inspection
.Set ohmmeter to )( 10 scale Connect meter leads to starter relay as shownIf resistance ,is less than infinite, the starter relay switch is not returning and must be replaced
Set ohmmeter to 10 seale Connect meter leads to starter relay as shown Activate starter relay switch by connecting 12 battery as shownIf the starter relay switch clicks and the ohmmeter indicates zero resistance, the starter relay switch is goodIf the metelr indicates high or infiniite (oo) resistance, the starter relay switch is defective and must be replaced
Reduction Gear: