PERIODIC MAINTENANCE

Insert thickness gauge between the valve end the adjusting screw on the rocker arm If the clearance is out of specification, adjust it to the specified range09900-20806: Thickness gauge 09917-14910: Tappet adjust drive Valve clearance (when cold): IN: 0.05 0.10 mm (0.002 0.004 in) EX: 0.10 0.15 mm (0.004 0.006 in) Valve clearance adjuster locknut: 10 Nm (1.0 kgf-m, 7.0 lb-ft)