2002-2009 Suzuki LT-F250 Ozark Service Manual, Page 71Get this manual

2002-2009 Suzuki LT-F250 Ozark Service Manual, Page 71


If the camshaft journal oil clearance measured exceeds the limit, measure the outside diameter of camshaftReplace either the cylinder head set or the camshaft if the clearance is incorrectCamshaft journal O.DStandard: 21.959 21.976 mm (0.8645 0.8652 in) 09900-20205: Micrometer (0 25 mm) CAMSHAFT RUNOUT Measure the runout with dial gaugeReplace the camshaft if the runout exceeds the limitCamshaft runout (INEX) Service Limit: 0.10 mm (0.004 in) 09900-20607: Dial gauge (1100, 10 mm) 09900-20701: Magnetic stand 09900-21304: V-block (100 mm)