2005-2007 Polaris Ranger 500 service manual, Page 297Get this manual

2005-2007 Polaris Ranger 500 service manual, Page 297

ELECTRICAL Ground Test
GROUND Test Test Procedure The PDM uses pin for ground wire; it connects to the PDM through connector SSCB1Check for continuity between the brown wire at SSCBand the terminal block ground postThere should be continuity to ground on the wire to pass
What does passing Wire harness and connections are acceptablethis test indicate? What does failing Wire harness andor connections are suspectthis test indicate?

Static Stator Test
Static Stator Test Test Procedure Disconnect the stator wire harness connector from the PDMMeasure resistance) between each of the three yellow leads, for example: Y1 to Y2, Y1 to Y3, Y2 to Y3Resistances should be 0.43 20 with no continuity to ground to pass this test
What does passing Passing these tests indicates the stator is operating normallythis test indicate? What does failing If resistance values are not near equal on all three legs, there is likely broken or shorted leg in the statorthis test indicate?

Run Signal Test