Water Temperature Switch Inspection

Remove:Temperature Water

Switch (see Water Temperature Switch Removal in the Cooling System chapter) Suspend the switch [A] in container of coolant so that the temperature sensing projection and threaded portion are submergedSuspend an accurate thermometer [B] in the coolant
The switch and thermometer must not touch the container sides or bottom
container over source of Place thethe temperature of the coolantheat and gradually raise while stirring the

coolant gentlyUsing the hand tester, measure the internal resistance of the switch across the connector and the body at the temperatures shown in the tableIf the hand tester does not show the specified values, replace the switchWater Temperature Switch Resistance Rising Temperature: From OFF to ON at 112 118C (234 244F) Falling Temperature: From ON to OFF at 108 111C (226 232F) ON: Less than 0.5 OFF: More than M