2005 Kawasaki KAF400 Mule 600 and Mule 610 4x4 Service Manual, Page 356Get this manual

2005 Kawasaki KAF400 Mule 600 and Mule 610 4x4 Service Manual, Page 356

16-26 ELECTRICAL SYSTEM Charging System
Stator Coil Resistance

Disconnect the alternator leads connectorthe stator coil resistance Measure an ohmmeter between the alternator leadsConnect
Stator Coil Resistance Standard: 0.3 or less

If the meter does not read as specified, replace the alternator statorIf the coil has normal resistance, but the voltage inspect showed the alternator to be defective; then the rotor magnets have probably weakened, and the rotor must be replaced
RegulatorRectifier Inspection
Remove the regulatorrectifier [A]Rectifier Circuit Test Check the resistance in both directions between the terminals following the tableTester Connection W-GW1, W-GW2 BKY-GW1, BKY-GW2