17-70 ELECTRICAL SYSTEM Actuator Control System
2WOl4WO Actuator Removal
Remove: Right Inner Cover Rear (see Inner Cover Rear Removal in Frame chapter) Actuator Lead Connector [A]

Remove: Actuator Mounting Bolts [A] Actuator [B]

2WOl4WO Actuator Installation
When installing the pin [A], apply engine oil to the rod of the actuator and install the collar [B] on the actuator and then press the pin Apply grease to the a-ring [C] Apply molybdenum disulfide grease to the collar Insert the collar into the groove [D] of the shifter so that the long side [E] faces downward