16-36 ELECTRICAL SYSTEM Ignition System
Ignition Coil Primary Peak Voltage Inspection NOTE
Be sure the battery is fully chargedplug cap Remove the spark the spark (see Spark Plug Removal), but do not remove plugMeasure the primary peak voltage as follows Connect commercially peak voltage adapter [A] to the hand tester [B] (250 DC range)Install the needle adapters [C] on the peak voltage adapter leadsSpecial ToolsHand Tester: 570011394 Needle Adapter Set: 570011457 Recommended ToolPeak Voltage Adapter Type: KEK-54-9-B Brand: KOWA SEIKI

Insert the needle adapter inside the seal of the GW (front) or BLW (rear) lead in the ignition coil [D] until the needle reaches the terminal in the ignition coilInstall new spark plug [E] into the spark plug cap, and ground it to the engine
WARNING
To avoid extremely high voltage shocks, do not touch the spark plugs or tester connectionsignition Turn the with the switch ON, rotate the engine forseconds transmission in neutral to measure the