2004-2006 Kawasaki Prairie 700 4x4, KVF 700 4x4 service manual, Page 437Get this manual

2004-2006 Kawasaki Prairie 700 4x4, KVF 700 4x4 service manual, Page 437

ELECTRICAL SYSTEM 17-47 Electric Starter System
Measure the diameter [AJ of the commutatorReplace the starter motor with new one if the commutator diameter is less than the service limitCommutator Diameter StandardService Limit: 28 mm (1 .10 in 27 mm (1 .06 in

Armature Inspection Using the range, measure the resistance between
any two commutator segments [A]If there is high resistance or no readin (00) between any two segments, winding is openReplace the starter motor Using the highest range, measure the resistance between the segments and the shaft [8) If there is any reading at all, the armature has shortReplace the starter motor
OEven if the foregoing checks show the armature to be good, it may be defective in some manner not readily detectable with the hand testerIf all other statter motor and starter motor circuit components check good, but the statter motor still does not turn over or only turns over weakly, replace the statter motor with new one