2004 John Deer Buck Utility ATV 500, 500EX and 500EXT Service Manual, Page 53Get this manual

2004 John Deer Buck Utility ATV 500, 500EX and 500EXT Service Manual, Page 53

V01C0SA
V01c0Sa2.EPS
V01C17A

Install new O-ring no21 in anti-vibration bushing groovesV01c17a2.EPS

Before starting the engine, remove spark plugs no15 and ground them on engine or frameRun starter about thirty secondsThis operation activates the oil pumpReinstall spark plugs and check if engine runs correctlyLet the engine idle for one minute to ensure full charge of hydraulic valve liftersCalibrate STPS, GBPS and TPS (AUTOSHIFT model)Refer to ELECTRIC SHIFT SYSTEM
Apply grease on anti-vibration bushings and insert in engine support, one on each sideFor installation, use 152 mm (6 in) bolt for LH side and 102 mm (4 in) for RH side, three washers and nutRefer to the following illustration