ELECTRIC STARTER
TROUBLESHOOTING
NOTE: The starter motor should operate when the transmission is in heutral or when the transmission is in drive and the front brake lever is squeezed Make sure the engine stop switch is turned "O" before startirtg the engineThe starter motor does not operate with the engine stop switch turned OFFStarter motor does not turn 1Fuse Inspection Check for blown main fuse (30 A) or IGN fuse (10 A)Is the fuse blown? YES NOReplace the fuse- GO TO STEP 2
2Battery Inspection Check that the battery is fully charged and in good conditionIs the battery in good condition? YES NOGO TO STEP 3- Charge the battery (page 20-7)
3Starter Relay Switch Operation Inspection Check the operation of the starter relay switch (page 22-12)Does the starter relay switch click? YES NOGO TO STEP 4- GO TO STEP 5