2006 Honda TRX680 Rincon Factory Service Manual, Page 167Get this manual

2006 Honda TRX680 Rincon Factory Service Manual, Page 167

FUEL SYSTEM (PGM-FI)
BANK ANGLE SENSOR
INSPECTION
Remove the right inner fender (page 3-9)Disconnect the bank angle sensor 3P (Green) connector and connect the inspection test harnessTOOL: Inspection test harness

07GMJ-ML80100

Turn the ignition switch ON and engine stop switch to "O"Measure the voltage between the test harness terminalsCONNECTION White(+)Red(-) Red(+)Green(-) Turn the ignition switch OFFDo not disconnect Remove the right bolt and loosen the left boltthe bank angle Remove the bank angle sensor from left side of sensor connector grommetduring inspection
STANDARD Battery voltage 0-1 V

Connect the bank angle sensor 3P (Green) connector
Before you per- Place the bank angle sensor is normal position as form this test, turn shown, and ignition switch ON and engine stop the ignition switch switch "O", bank angle sensor is normal if the OFF, then turn the engine stop relay clicks and power supply is closedignition switch ON Incline the bank angle sensor approximately 70 to and engine stop the left or right with keep the ignition switch ON and switch 'O"