IGNITION SYSTEM IGNITION PULSE GENERATOR PEAK VOLTAGE Disconnect the ignition control module (lCM) 4P connectorConnect the peak voltage tester or adaptor probes to the wire harness side connector terminalsCONNECTION: Blueyellow (+1- Yellowwhite

4P CONNECTOR

Turn the igniti on switch to ONCrank the engine with the starter motor and measure the ignition pulse generator peak voltagePEAK VOLTAGE: 0.7 minimum

If the peak voltage measured at the ICM is abnormal, measure the peak voltage at the ignition pulse generatorDisconnect the alternatorlignition pulse generator 3P connector and connect the peak voltage tester or adaptor probes to the ignition pulse generator side connector terminalsCONNECTION: Blueyellow 1+1Yellowwhite H