ELECTRIC SHIFT PROGRAM (ESP; FEFPE model) 6Angle Sensor Ground line Short Circuit
Inspection

Turn the ignition switch to OFFCheck for continuity between the Greenblue wire terminal of the wire harness side sensor connector and groundANGLE SENSOR CONNECTOR (Viewed from the terminal side)

Is there continuity?

- Check the angle sensor connector for

loose or corroded terminal- Repair short circuit in the Greenblue wire
Greenblue

7Angle Sensor Inspection Check that the resistance between the Yellowl
blue and Greenblu terminals of the sensor connector varies with the gea position (page 22-20)