2005-2011 Honda FourTrax Foreman TRX500 FE/FPE/FM/FPM/TM Service Manual, Page 466Get this manual
ELECTRIC SHIFT PROGRAM (ESP; FEFPE model) 6Angle Sensor Ground line Short Circuit
Inspection
Turn the ignition switch to OFFCheck for continuity between the Greenblue wire terminal of the wire harness side sensor connector and groundANGLE SENSOR CONNECTOR (Viewed from the terminal side)
Is there continuity?
- Check the angle sensor connector for
loose or corroded terminal- Repair short circuit in the Greenblue wire
Greenblue
7Angle Sensor Inspection Check that the resistance between the Yellowl
blue and Greenblu terminals of the sensor connector varies with the gea position (page 22-20)
From neutral to 5th gear: Resistance increase From 5th gear to neutralResistance decreases