ELECTRIC STARTER
TROUBLESHOOTING
The starter motor should operate when the transmission is in neutral or when the transmission is in drive and the front brake lever is squeezed Make sure the engine stop switch is turned to RUN before starting the engineThe starter motor does not operate with the engine stop switch turned to OFFStarter motor does not turn 1Fuse Inspection Check for blown main fuse (30 A) or IGN fuse (10 A)Is the fuse blown? YES NO Replace GO TO

the fuseSTEP 2
2Battery Inspection Check that the battery is fully charged and in good conditionIs the battery in good condition? YES NO GO TO STEP 3Charge the battery (page 19-7)