2000-2003 Honda TRX350 Rancher factory service manual, Page 349Get this manual

2000-2003 Honda TRX350 Rancher factory service manual, Page 349

ELECTRIC SHIFT PROGRAM (ESP: TEFE models) Connect the control unit 22P (gray: '00 '02, brown: After '02) connectorMeasure the input voltage between the Blackred) and Bluegreen) terminals of the angle sensor 3P connector with the ignition switch turned to ON''STANDARD: 4.7 5.3 If the input voltage is abnormal, or if there is no input voltage, check for an open or short circuit in the wire harness, or loose or poor connections in the wire harness3P CONNECTOR

REMOVAL
Remove the two bolts and sensor coverDisconnect the 3P connectorRemove the two socket bolts, washers and angle sensorBOLTS