2000-2003 Honda TRX350 Rancher factory service manual, Page 14Get this manual

2000-2003 Honda TRX350 Rancher factory service manual, Page 14

GENERAL INFORMATION BATTERYCHARGING SYSTEM ITEM Battery Capacity Current leakage Voltage (20C68F) Charging current Alternator Fully charged Needs charging Normal Quick

SPECIFICATIONS 12 12 Ah mA max(Equipped with digital meter) 0.1 mA max(No digital meter) 13.0 13.2 Below 12.3 1.4 10 6.0 1.0 0.245 kW5,000 rpm 0.1 1.0

Capacity Charging coil resistance (20C68F)

IGNITION SYSTEM
Spark plug

SPECIFICATIONS DPR7EA-9 (NGK)X22EPR-U9 (DENSO) DPR6EA-9 (NGK)X20EPR-U9 (DENSO) 0.8 0.9 mm (0.03 0.04 in) 100 minimum 0.7 minimum 11 BTDC at idle Unit: mm (in) STANDARD 12.5 (0.49) SERVICE LIMIT 9.0 (0.35)

Standard For cold climate (below 5C41F)