1999-2002 TRX400EX Fourtrax Service Manual, Page 135Get this manual

1999-2002 TRX400EX Fourtrax Service Manual, Page 135

ALTERNATORSTARTER CLUTCH Remove the nut, seven bolts and the left crankcase cover
Removethe gasket and dowel pinsRemovethe starter reduction gear shaft and gear
STATOR REMOVALINSTALLATION
Removethe bolt and wire clampRemove the two ignition pulse generator bolts and wire clampRemovethe three stator boltsRemove the wire grommet and statorlignition pulse generator assembly from the left crankcase coverInstall the statorignition pulse generator assembly onto the left crankcase coverApply sealant to the wire grommet seating surface and install it into the cover groove properlySTATORInstall the stator bolts and tighten them securelyApply locking agent to the ignition pulse generator bolt threadsInstall the wire clamp onto the ignition pulse generator and tighten the two bolts securelyApply locking agent to the wire clamp bolt threadsInstall the wire clamp and tighten the bolt securelyBOLTS