1998-2004 Honda Foreman 450 factory service manual, Page 392Get this manual

1998-2004 Honda Foreman 450 factory service manual, Page 392

ELECTRIC STARTER INSTALLATION Install the starter motor with the two mounting boltsConnect the starter cable to the motorInstall the right engine side cover (page 6-10)
STARTER RELAY SWITCH
OPERATION INSPECTION
Remove the seat and battery holder bracketDepress the starter switch button with the ignition switch ONThe coil is normal if the starter relay switch clicks
VOLTAGE INSPECTION
If the switch "CLICK" is not heard, disconnect the relay connectorMeasure the voltage between the YellowRed (+) and Light green wire terminals of the wire harness sideThe battery voltage should be indicated when the starter switch button is depressed with the ignition switch ON and the transmission in neutral