1998-2004 Honda Foreman 450 factory service manual, Page 375Get this manual
BATTERYCHARGING SYSTEM
REG ULATORRECTIFIER
SYSTEM INSPECTION
Disconnect the regulatorrectifier connectorand check it fo loose contact or corroded terminals
REGULATORRECTIFIER CONNECTOR
If the regula te voltage reading (see page 17-8) is out the specification, measure the vo lta ge between connector terminals (wire harness side) as follows: Item Battery charging line Charging coil li ne Ground li ne Terminal Red (+and ground Specification Battery voltage should register
REGULATORRECTIFIER CONNECTOR