IG NITION SYSTEM With thigniti on co i.mary re connected, connect the peak voltag,e adaptor or peak volta,ge tester to th ignition coilCONNECTION: Blstl(Yeliow terminalBodV ground (+1

IGNITION COIL

PEAK VOLTAGE

ADAPTER

Turn the engine stop switch toRUN "
Crank the engine with the starter motor and read ignition coil primary pea,k voltagePEAK VOLTAGE: 100 minimum

If the peak voltage is abnormal:, check for an open circuit or poor connect ion in BlacWYeUow ireIf no defects are found in the harnessrefer to the troubl'eshooting chart on page 18-3
IGNITION PULSE GENERATOR PEAK VOLTAGE