1989 Honda FL400R Pilot Service Manual, Page 223Get this manual

1989 Honda FL400R Pilot Service Manual, Page 223

BATTERYCHARGING SYSTEM SPECIFICATIONS
ITEM Battery Capacity
Charging current

STANDARD 12V-12 AH At standard: 1.4 At standard: 5-10 hours Fully charged At maximum: At maximum: hour 13.0-13.2 0.2 kW5,000 rpm

Charging time Voltage Alternator capacity
Regulatorrectifier

Type Regulated voltageamperage

Transitorized non-adjustable regulator

13.5-15.5 V0.5 A(5,000 rpm) 0.2-0.6

Charging coil resistance

Kowa digital multi-meter or Sanwa electric tester or Kowa electric tester Honda battery tester Christie battery charger

07411-0020000 or KS-AHM-32-003 (U.S.Aonly) 07308-0020001 TH-5H 07GMJ-0010000(U.S.Aonly) #MC10122 (U.S.Aonly)