2006 Bombardier Outlander Max Series Factory Service Manual, Page 294Get this manual
Section 07 TRANSMISSION Subsection 01 (CONTINUOUSLY VARIABLE TRANSMISSION (CVT))
1Ball bearing 2Fixed half of driven pulley
CAUTION: Do not use hammer, use press ma1Caliper Sliding half 3Contact surface AWear to be measured
chine only
WEAR ON CONTACT SURFACE
SERVICE LIMIT
1 .00 mm (.039 in)
Spring Measure spring free length and squarenessIf spring is out of specification, replace by newSPRING FREE LEIIGTH
SERVICE LIMIT