Section 07 TRANSMISSION Subsection 01 (CONTINUOUSLY VARIABLE TRANSMISSION (CVT))
Fixed Half
Check ba ll bearing no24 for free play and smooth operation Rep lace if necessaryCheck shaft no25 for heavy wear age Replace if necessary
or visible dam -

If the shaft is removed, measure bushing diameter with dial bore ga uge Measu ring point must be at least mm (14 in) from bushing edge This bushing is not replaceable Replace fixed half if bushing no28 is out of specificationVisually inspect coatingsBUSHING BORE DIAMETER NOMIAL SERVICE LIMIT 30 .000 to 30.020 mm (1 .18 to 1.182 in) 30.200 mm (1 .189 in)
1Con tact surfaces for power train 2Caliper AWidth to be measured due to wear on contact surface